Sample Release Reagent
Sample Release Reagent

  • 4196
1 mL
HMD3504-01
8 mL
HMD3504-02
100 mL
HMD3504-03
1000 mL
HMD3504-04

Cat. No: HMD3504

Storage stability: Store at room temperature

Technical Support

Product Description

HZYMES BIOTECH develops Sample Release Reagent for molecular POCT diagnostic scenarios. For the two systems of direct amplification LAMP and direct amplification PCR, there is no need for nucleic acid extraction. The crude lysate of the sample can be directly amplified, the target gene can be accurately detected, the sample detection time can be further shortened, which perfectly matches the application requirements of molecular POCT. It is suitable for nasal swabs, throat swabs and other sample types. The processed samples can be directly used for real-time fluorescence quantitative PCR or LAMP detection, and the same results as conventional extraction methods can be achieved without complicated nucleic acid extraction operations.



Product Information

Product NameCat. No.Size
Sample Release ReagentHMD3504-011 mL
HMD3504-028 mL
HMD3504-03100 mL
HMD3504-041000 mL


Transportation and Storage Conditions

Transport at room temperature; Store at room temperature



Quality Control

Functional detection – quantitative qPCR: The 800μl Sample Release Reagent system was amplified with 1000copies Novel Pseudovirus, one nasal swab sample, resulting similar amplification curves and ΔCt values within ± 0.5 Ct.



Experimental Procedures

1. Take 800 μl Sample Release Reagent and spread the lysis solution into 1.5 mL sampling tube

2. Take the nasal swab or throat swab with the swab; nasal swab sampling procedure: take the sterile swab and put it into the nostrils, slowly advance to about 1.5 cm deep, gently rotate 4 times against the nasal mucosa for more than 15 seconds, then repeat the same operation on the other nasal cavity with the same swab. throat swab sampling procedure: take the sterile swab and gently, quickly wipe the pharyngeal tonsils and rear pharyngeal wall 3 times.

3. Place the swab immediately in the sampling tube. The swab head should be rotated and mixed in the storage solution for at least 30 seconds to ensure that the sample is fully eluted in the sampling tube.

4. Incubation at room temperature (20 ~ 25°C) for 1 min, the preparation of lysis buffer is completed.

5. Both 25μl system RT-PCR and RT-LAMP were compatible with 10 μl amount of template addition for detection experiments.



Notices

1. The minimum amount of sample direct lysate corresponding to a single swab can be adjusted to 400μl, which can be adjusted according to the testing needs.

2. Once the sample processed by the sample release reagent, it is recommended to conduct the next phase of test as soon as possible, the interval waiting time is preferably less than 1 hour.

3. The pH of the sample lysate is acidic, and the detection system needs to have a certain buffer. It is suitable for most PCR, RT-PCR, and LAMP fluorescence detection with pH buffer, but not suitable for LAMP colorimetric detection without buffer.

Message
Order Inquiry
Name *
Company *
Position *
Tel *
Mail *
Nation *

Do you have purchasing intention??

Requirement Description

Please contact on WhatsApp

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

  • iso_copy_copy
  • iso_copy
  • iso
  • iso_copy_copy
  • iso_copy
  • iso
Contact Us

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China.

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

Copyright © Hzymes Biotechnology Co., Ltd. All Rights Reserved Web design

Site Map | Legal Notice | Privacy Policy |

Contact Us