Blood Sample Release Reagent
Blood Sample Release Reagent

  • 181
  • 182
1 mL
HMD3506-01
8 mL
HMD3506-02
100 mL
HMD3506-03
1000 mL
HMD3506-04

Cat. No: HMD3506

Transportation and storage conditions: Transported at room temperature, stored at room temperature.

Technical Support

Blood Sample Release Reagent (For Direct LAMP Amplification)


Blood Sample Release Reagent is a sample preparation solution designed for molecular POCT (Point-of-Care Testing) workflows. It enables direct amplification from crude blood lysates without nucleic acid extraction, making it ideal for rapid LAMP-based molecular diagnostics. By simplifying sample processing, it significantly shortens turnaround time while maintaining reliable detection performance comparable to conventional extraction-based methods.


This reagent is compatible with blood samples collected in common anticoagulant tubes, including heparin sodium, EDTA, and sodium citrate, and is optimized for use in direct LAMP fluorescent detection systems.



Product Overview


The Blood Sample Release Reagent is developed to support extraction-free nucleic acid amplification in LAMP assays. It lyses blood samples efficiently and releases target nucleic acids directly into a format suitable for amplification, eliminating the need for time-consuming and labor-intensive extraction procedures.


After treatment, the processed sample can be directly added into a LAMP reaction system for rapid detection of target genes. The workflow is designed to improve efficiency in molecular POCT applications, enabling faster decision-making in clinical and field-testing environments.



Key Features


Extraction-Free Sample Preparation


Enables direct amplification from crude blood lysates, removing the need for nucleic acid purification steps and reducing overall workflow complexity.


Rapid Molecular Testing Workflow


Shortens sample-to-result time by allowing immediate downstream LAMP amplification after sample processing.


High Compatibility with Blood Samples


Suitable for blood collected in:

• Heparin sodium tubes

• EDTA tubes

• Sodium citrate tubes


Optimized for LAMP Fluorescent Detection


Designed for compatibility with fluorescence-based LAMP systems that include buffering capacity, ensuring stable amplification performance.


Flexible Sample Processing Ratio


Supports adjustment of reagent-to-sample ratios, such as processing 10 μL blood with ~500 μL reagent, allowing optimization based on assay requirements.


Simplified POCT Workflow


Reduces operator steps and minimizes contamination risk by eliminating nucleic acid extraction procedures.



Applications


The Blood Sample Release Reagent is widely applicable in molecular diagnostics and POCT LAMP workflows, including:

• Infectious disease rapid detection using blood samples

• Point-of-care molecular diagnostics (POCT)

• Field testing and decentralized laboratory settings

• LAMP-based pathogen detection assays

• Rapid screening workflows in clinical laboratories

• Molecular testing in resource-limited environments


Note:


This reagent is suitable for LAMP fluorescent detection systems with buffering capacity. It is not recommended for buffer-free LAMP colorimetric detection systems due to its alkaline formulation.



FAQ


What is Hzymes’ Blood Sample Release Reagent used for?


It is designed for molecular POCT diagnostics to enable direct amplification from crude blood lysates without nucleic acid extraction, significantly reducing sample processing time.


What sample types are compatible with this reagent?


It is compatible with whole blood and can be adapted for other clinical sample types depending on assay optimization.


Can the released lysate be directly used in LAMP or PCR?


Yes. The reagent is optimized for direct downstream amplification in LAMP systems and selected PCR workflows after proper system validation.


Does this reagent affect amplification efficiency?


It is formulated to minimize PCR/LAMP inhibition while maintaining stable target detection performance in crude sample systems.


Is nucleic acid purification still required?


No purification is required for routine use, which makes it suitable for rapid POCT workflows.

Message
Order Inquiry
Name *
Company *
Position *
Tel *
Mail *
Nation *

Do you have purchasing intention??

Requirement Description

Please contact on WhatsApp

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

  • iso_copy_copy
  • iso_copy
  • iso
  • iso_copy_copy
  • iso_copy
  • iso
Contact Us

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China.

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

Copyright © Hzymes Biotechnology Co., Ltd. All Rights Reserved Web design

Site Map | Legal Notice | Privacy Policy |