PNGase F-Fast (Glycerol Free)
PNGase F-Fast (Glycerol Free)

  • 614
  • 615
50μL
HBP003004

Cat. No: HBP003004

Storage condition:  

Transport Condition: -25~-15℃.
Storage condition: -25~-15℃, the freezing and thawing times of the product are less than 5 times. It is recommended to store the product in small doses after thawing for the first time. After thawing for short term use, it can be stored at 2~8℃, and the recommended time is not more than 30 days.

Technical Support

Product Overview


PNGase F is the most efficient enzymatic method to remove nearly all N-glycans from glycoproteins. PNGaseF digests the glycosidic bond between the innermost N-acetylglucosamine and asparagine residues. It cleaves N-glycans attached to glycoproteins, including high-mannose, hybrid, and complex oligosaccharide glycoforms.



Key Features


Efficient N-glycan release enzyme


PNGaseF-Fast enables enzymatic removal of N-linked glycans from glycoproteins by cleaving the bond between the innermost N-acetylglucosamine and asparagine residues. It is applicable to high-mannose, hybrid, and complex N-glycan structures.


Preservation of glycan core structure


After enzymatic digestion, released N-glycans retain their core structures, supporting downstream analytical applications.


Rapid reaction setup


Supports fast deglycosylation workflows with a typical setup time of approximately 10 minutes at 50 °C under recommended conditions.


Glycerol-free formulation


Glycerol-free composition is suitable for applications where glycerol interference should be minimized, such as HPLC and mass spectrometry-based analyses under specific workflow requirements.


High purity


Purity is typically ≥95% as determined by standard analytical methods.


Flexible reaction compatibility


Compatible with both denaturing and non-denaturing digestion conditions depending on experimental needs.


Multiple product formats available


Different formats are available to support diverse application requirements (e.g., HBP003006/ HBP003013 /HBP003005).



Applications


N-glycan release for analytical workflows


Used for enzymatic removal of N-linked glycans in workflows typically performed at 50 °C for downstream structural analysis.


CE and LC/LC-MS-based glycan analysis


Suitable for sample preparation in capillary electrophoresis (CE), HPLC, and LC-MS-based N-glycan profiling applications.


Glycoprotein modification for downstream applications


Applied in workflows requiring removal of N-glycans prior to protein modification or bioconjugation processes, including ADC-related research applications depending on experimental design.



Performance Data


Enzymatic digestion efficiency





FAQ


What components are included in the PNGase F-Fast (Glycerol Free) system?


The system typically includes PNGase F-Fast (glycerol-free formulation) and 5×PNGaseF-Fast buffer, designed for rapid N-linked glycan release workflows.


What is the advantage of the glycerol-free formulation?


The glycerol-free formulation is designed for applications where glycerol may interfere with downstream analysis, such as HPLC and LC-MS-based workflows, under specific experimental conditions.


Can this system be used under both denaturing and non-denaturing conditions?


Yes. PNGase F-Fast (Glycerol Free) is compatible with both denaturing and non-denaturing digestion conditions, depending on sample type and experimental requirements.


What are the recommended reaction conditions?


The system supports rapid deglycosylation workflows, with a typical reaction setup of approximately 10 minutes at 50 °C, followed by incubation according to the specific protocol and sample characteristics.


Can reaction conditions be optimized?


Yes. Enzyme amount, incubation time, and reaction conditions can be adjusted based on glycoprotein type, glycan complexity, and downstream analytical needs.


Protocols under denaturing and non-denaturing conditions

Steps Denaturing Reaction Conditions Non-Denaturing Reaction Conditions
1 Dissolve100 µg of antibody/glycoprotein with deionized water Dissolve100 µg of antibody/glycoprotein with deionized water
Add deionized water to the total volume of 16 µL Add deionized water to the total volume of 16 µL
2 80 °C 2min, then cool on ice; /
3 Add 4µl of 5×PNGase F-Fast buffer, gently aspirate and dispense to mix Change the buffer to 0.25M PB (pH 7.5~8.0)
4 Add 1µL of PNGase F-Fast Add 1µL of PNGase F-Fast
5 50°C 10min; 50°C ≥0.5~1h or 37°C≥4h(can be adjusted if needed)
Message
Order Inquiry
Name *
Company *
Position *
Tel *
Mail *
Nation *

Do you have purchasing intention??

Requirement Description

Please contact on WhatsApp

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

  • iso_copy_copy
  • iso_copy
  • iso
  • iso_copy_copy
  • iso_copy
  • iso
Contact Us

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China.

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

Copyright © Hzymes Biotechnology Co., Ltd. All Rights Reserved Web design

Site Map | Legal Notice | Privacy Policy |