AMPPD Chemiluminescence Solution
AMPPD Chemiluminescence Solution

  • 368
  • 369
HH7601-01
HH7601-02

Cat. No: HH7601 

Stability: 2-8℃ can be stable for more than 2 year.

Technical Support

Product Overview


AMPPD is an ultra-sensitive chemiluminescent substrate for alkaline phosphatase in biochemistry. Under buffer conditions, AMPPD undergoes catalytic hydrolysis in the presence of alkaline phosphatase to decompose and produce intense luminescent signals, and luminescence intensity presents an excellent linear correlation with ALP concentration. It is applicable to magnetic particle chemiluminescence, microplate-based chemiluminescence and other detection platforms.


Featuring a wide linear detection range, AMPPD requires no special conjugate of substrate-antigen/antibody, delivering convenient and user-friendly operation for diversified testing applications. Hzymes AMPPD chemiluminescent substrate is developed for chemiluminescence immunoassays based on alkaline phosphatase labeling system."



Key Features


Sensitive Detection


Capable of detecting ALP concentrations below 10¹ mol/mL and target proteins at levels as low as 5 pg, supporting applications requiring high analytical sensitivity.


Stable Signal Output


Produces a stable luminescent plateau for up to 60 minutes, providing flexibility for signal acquisition and high-throughput testing workflows.


Broad Linear Range


Exhibits a strong linear relationship between ALP concentrations ranging from 50 to 50,000 pg/mL and photon counts, supporting quantitative analysis across a wide detection range.


Good Storage Stability


Stable for up to 15 months when stored at 2–8°C protected from light, supporting routine use and inventory management.


Ready for Multiple Detection Platforms


Suitable for magnetic particle chemiluminescence, microplate-based chemiluminescence, and other ALP-based detection systems without requiring specialized substrate-antigen or substrate-antibody conjugates.



Applications


Chemiluminescent Immunoassays


Suitable for high-sensitivity detection in alkaline phosphatase-labeled immunoassay systems, including automated and manual testing platforms.


Magnetic Particle Chemiluminescence


Applicable to magnetic particle-based chemiluminescent assays used in immunodiagnostic workflows.


Microplate-Based Detection


Compatible with microplate chemiluminescence assays for research and diagnostic assay development.


Molecular Biology and Enzyme Activity Analysis


Can be used in molecular biology applications and alkaline phosphatase activity studies requiring chemiluminescent signal detection.



Performance Data


Low Background and Ultra-high Signal-to-noise Ratio, Improving Reagent Sensitivity


Comparison of Signal-to-Noise Ratio Measured Values of AMPPD Chemiluminescent Substrates from Different Manufacturers



Luminescence Kinetic Curves of AMPPD Chemiluminescent Substrates from Different Brands



Compared with peer products, Hzymes AMPPD luminescent solution features notably lower background and higher signal-to-noise ratio.


Good Thermal Stability, Enhancing Reagent Stability


After 28-day accelerated test at 37 °C, the change in AMPPD chemiluminescence value was ≤10%.




High Detection Repeatability and Consistent Performance Between Batches


Batch-to-batch variation test was conducted on Hzymes AMPPD chemiluminescent substrate solution, with CV ≤ 5%, proving its excellent detection repeatability.



Note: Test conditions: 5 μL enzymes + 150 μL substrate solution, enzyme activity 0.07 MU. All data were obtained using Lumistation 1800.



FAQ


What are the recommended storage conditions and shelf life of this product?


The product should be stored at 2–8°C and protected strictly from light to maintain optimal performance. Please refer to the product specification sheet for validated shelf-life information.


What is the recommended usage or dosage for this product?


The recommended usage is 100–200 μL per reaction. The optimal volume may vary depending on the assay format and instrument settings.


Do you offer customization services?


Yes. We provide customization services to support specific application requirements, including formulation and packaging options.


Do you provide OEM or private-label manufacturing services?


Yes. We offer OEM and private-label manufacturing services to meet customers' branding and product development needs.


What are the shipping conditions and typical lead times?


The product is typically shipped under temperature-controlled conditions with light protection.

In stock: Typical lead time is 2–3 weeks

Out of stock: Typical lead time is 8–12 weeks


Is this product compatible with different chemiluminescence platforms?


Yes. The product is suitable for magnetic particle chemiluminescence, microplate-based chemiluminescence, and other ALP-based detection platforms.

Message
Order Inquiry
Name *
Company *
Position *
Tel *
Mail *
Nation *

Do you have purchasing intention??

Requirement Description

Please contact on WhatsApp

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

  • iso_copy_copy
  • iso_copy
  • iso
  • iso_copy_copy
  • iso_copy
  • iso
Contact Us

Service Hotline: +86 400-808-5320

Large-scale production base: Building 6, Precision Medical Industry Base, Wuhan, China.

Logistics & Supply Chain Center:417 Main St, Little Rock, AR 72201. United States.

Global Marketing Center: Hzymes Building, Fengxian District, Shanghai, China.

Copyright © Hzymes Biotechnology Co., Ltd. All Rights Reserved Web design

Site Map | Legal Notice | Privacy Policy |